Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 259
Filter
1.
J. bras. nefrol ; 46(2): e2024PO02, Apr.-June 2024.
Article in English | LILACS-Express | LILACS | ID: biblio-1550492

ABSTRACT

ABSTRACT The desperate attempt to improve mortality, morbidity, quality of life and patient-reported outcomes in patients on hemodialysis has led to multiple attempts to improve the different modes, frequencies, and durations of dialysis sessions in the last few decades. Nothing has been more appealing than the combination of diffusion and convection in the form of hemodiafiltration. Despite the concrete evidence of better clearance of middle weight molecules and better hemodynamic stability, tangible evidence to support the universal adoption is still at a distance. Survival benefits seen in selected groups who are likely to tolerate hemodiafiltration with better vascular access and with lower comorbid burden, need to be extended to real life dialysis patients who are older than the population studied and have significantly higher comorbid burden. Technical demands of initiation hemodiafiltration, the associated costs, and the incremental benefits targeted, along with patient-reported outcomes, need to be explored further before recommending hemodiafiltration as the mode of choice.


RESUMO A tentativa desesperada de melhorar a mortalidade, morbidade, qualidade de vida e desfechos relatados pelos pacientes em indivíduos em hemodiálise levou a diversas tentativas de aprimorar os diferentes modos, frequências e durações das sessões de diálise nas últimas décadas. Nada foi mais atrativo do que a combinação de difusão e convecção na forma de hemodiafiltração. Apesar das evidências concretas de melhor depuração de moléculas de peso médio e melhor estabilidade hemodinâmica, evidências tangíveis para apoiar a adoção universal ainda estão distantes. Os benefícios de sobrevida observados em grupos selecionados que provavelmente toleram a hemodiafiltração com melhor acesso vascular e com menor carga de comorbidades precisam ser estendidos aos pacientes reais em diálise, que são mais velhos do que a população estudada e apresentam uma carga de comorbidades significativamente maior. As exigências técnicas do início da hemodiafiltração, os custos associados e os benefícios incrementais almejados, juntamente com os desfechos relatados pelos pacientes, precisam ser melhor explorados antes de se recomendar a hemodiafiltração como o modo de escolha.

2.
Arq. bras. cardiol ; 120(12): e20230087, dez. 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1527797

ABSTRACT

Resumo Fundamento O Teste de Caminhada de seis Minutos (TC6M) é comumente usado para avaliar pacientes com insuficiência cardíaca. No entanto, vários fatores clínicos podem influenciar a distância percorrida pelos pacientes no teste. A cardiografia de impedância (CI) na avaliação morfológica é uma ferramenta útil para avaliar a hemodinâmica cardíaca de maneira não invasiva. Objetivo Este estudo teve como objetivo comparar as respostas de aceleração e desaceleração do Débito Cardíaco (DC), da Frequência Cardíaca (FC), e do Volume Sistólico (VS) ao TC6M de indivíduos com insuficiência cardíaca e fração de ejeção reduzida (ICFEr) com as de controles sadios. Métodos Este é um estudo transversal observacional. O DC, a FC, o VS e o Índice Cardíaco (IC) foram avaliados antes, durante e após o TC6M por CI. O nível de significância adotado na análise estatística foi 5%. Resultados Foram incluídos 27 participantes (13 com ICFEr e 14 controles sadios). A aceleração do DC e da FC foi significativamente diferente entre os grupos (p<0,01 e p=0,039, respectivamente). Encontramos diferenças significativas no VS, no DC e no IC entre os grupos (p<0,01). A regressão linear mostrou uma contribuição deficiente do VS à mudança no DC no grupo com ICFEr (22,9% versus 57,4%). Conclusão O principal resultado deste estudo foi o fato de que indivíduos com ICFEr apresentaram valores mais baixos de aceleração do DC e da FC durante o teste de exercício submáximo em comparação a controles sadios. Isso pode indicar um desequilíbrio na resposta autonômica ao exercício nessa condição.


Abstract Background The six-minute walk test (6MWT) is commonly used to evaluate heart failure (HF) patients. However, several clinical factors can influence the distance walked in the test. Signal-morphology impedance cardiography (SM-ICG) is a useful tool to noninvasively assess hemodynamics. Objective This study aimed to compare cardiac output (CO), heart rate (HR), and stroke volume (SV) acceleration and deceleration responses to 6MWT in individuals with HF and reduced ejection fraction (HFrEF) and healthy controls. Methods This is a cross-sectional observational study. CO, HR, SV and cardiac index (CI) were evaluated before, during, and after the 6MWT assessed by SM-ICG. The level of significance adopted in the statistical analysis was 5%. Results Twenty-seven participants were included (13 HFrEF and 14 healthy controls). CO and HR acceleration significantly differed between groups (p<0.01; p=0.039, respectively). We found significant differences in SV, CO and CI between groups (p<0.01). Linear regression showed an impaired SV contribution to CO change in HFrEF group (22.9% versus 57.4%). Conclusion The main finding of the study was that individuals with HFrEF showed lower CO and HR acceleration values during the submaximal exercise test compared to healthy controls. This may indicate an imbalance in the autonomic response to exercise in this condition.

3.
Int. j. morphol ; 41(6): 1751-1757, dic. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1528791

ABSTRACT

SUMMARY: To observe the effect of sevoflurane combined with brachial plexus block (BPB) in children with humeral fracture surgery and its effect on hemodynamics. 84 children who received surgical treatment of humeral fracture in our hospital from September 2019 to September 2022 were selected. According to different anesthesia methods, the children were divided into control group and study group. The control group only received laryngeal mask sevoflurane; the study group received laryngeal mask sevoflurane combined with BPB. The operation situation, hemodynamic indexes, stress level, pain and adverse reactions of children was observed. The postoperative awakening time in the study group was lower than control group, the postoperative pain onset time in the study group was higher than control group (P0.05). Postoperative 2h, the levels of serum cortisol, b-endorpin, norepinephrine and epinephrine in the study group were lower than control group (P0.05). Sevoflurane combined with BPB is helpful to shorten the postoperative awakening time of children with humeral fracture, reduce the degree of postoperative pain, improve hemodynamics, and reduce stress response, and has good safety.


El objetivo fue observar el efecto del sevoflurano combinado con bloqueo del plexo braquial (BPB) en niños con cirugía de fractura de húmero y su efecto sobre la hemodinámica. Se seleccionaron 84 niños que recibieron tratamiento quirúrgico de fractura de húmero en nuestro hospital desde septiembre de 2019 hasta septiembre de 2022. Según diferentes métodos de anestesia, los niños se dividieron en grupo control y grupo de estudio. El grupo control solo recibió sevoflurano en mascarilla laríngea; el grupo de estudio recibió sevoflurano con mascarilla laríngea combinado con BPB. Se observó la situación operatoria, índices hemodinámicos, nivel de estrés, dolor y reacciones adversas de los niños. El tiempo hasta el despertar postoperatorio en el grupo de estudio fue menor que el del grupo control, el tiempo de aparición del dolor postoperatorio en el grupo de estudio fue mayor que el del grupo control (P0,05). A las 2 horas postoperatorias, los niveles séricos de cortisol, β-endorfina, norepinefrina y epinefrina en el grupo de estudio fueron más bajos que los del grupo control (P 0,05). El sevoflurano combinado con BPB es útil para acortar el tiempo de despertar del posoperatorio de los niños con fractura de húmero, reduce el grado de dolor postoperatorio, mejora la hemodinámica y reduce la respuesta al estrés, además de tener buena seguridad.


Subject(s)
Humans , Male , Female , Child , Brachial Plexus Block , Sevoflurane/administration & dosage , Humeral Fractures/surgery , Anesthetics, Inhalation , Hemodynamics/drug effects
4.
Arch. cardiol. Méx ; 93(3): 267-275, jul.-sep. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1513579

ABSTRACT

Resumen Introducción: La confiabilidad de la presión sistólica arterial pulmonar por ecocardiografía transtorácica se encuentra limitada por su variabilidad para definir la hipertensión pulmonar. Objetivo: Conocer la variabilidad en la presión sistólica arterial pulmonar estimada por ecocardiografía en la hipertensión pulmonar. Métodos: En el periodo 2016-2020 se captaron sujetos con hipertensión pulmonar que tuvieron estimada la presión sistólica de la arteria pulmonar por ecocardiografía transtorácica y por cateterismo cardiaco derecho. Se obtuvieron sus variables demográficas. Los datos se analizaron con el estadístico descriptivo de Bland-Altman y el coeficiente de correlación intraclase (intervalo de confianza al 95%). Resultados: Se estudiaron 152 sujetos, edad 60 ± 12 años. Índice de masa corporal 27.64 ± 4.69 kg/m2. La presión sistólica de la arteria pulmonar por ecocardiografía transtorácica 58.99 ± 18.62 vs. cateterismo cardiaco 55.43 ± 16.79. Diferencia media (sesgo) -3.6 (29.1, -36.2) y coeficiente de correlación intraclase 0.717 (0.610, 0.794). Conclusiones: La variabilidad es amplia y el acuerdo es sustancial con la presión sistólica de la arteria pulmonar. Se aconseja estimarla solo como tamizaje de la hipertensión pulmonar.


Abstract Introduction: The reliability of pulmonary arterial systolic pressure by transthoracic echocardiography is limited by its variability to define pulmonary hypertension. Objective: To know the variability of pulmonary arterial systolic pressure estimated by echocardiography in pulmonary hypertension. Their demographic variables were obtained. Methods: From 2016-2020 subjects with pulmonary hypertension were recruited, with pulmonary artery systolic pressure estimated by transthoracic echocardiography and by right heart catheterization. Data were analyzed using the Bland-Altman descriptive statistic and the intraclass correlation coefficient (95% confidence interval). Results: 152 subjects, age 60 ± 12 years, were studied. Body mass index 27.64 ± 4.69 kg/m2. The pulmonary artery systolic pressure estimated by transthoracic echocardiography 58.99 ± 18.62 vs. cardiac catheterization 55.43 ± 16.79 mmHg. Mean difference (bias) -3.6 (29.1, -36.2) and intraclass correlation coefficient 0.717 (0.610, 0.794). Conclusions: Variability is wide, and agreement is substantial for pulmonary artery systolic pressure. It is recommended to estimate only as screening for pulmonary hypertension.

5.
Int. j. odontostomatol. (Print) ; 17(2): 216-223, jun. 2023. ilus, tab
Article in Spanish | LILACS | ID: biblio-1440347

ABSTRACT

La exodoncia de los terceros molares inferiores es uno de los procedimientos clínicos más comunes en el cual el control del dolor mediante el bloqueo anestésico del nervio alveolar inferior, bucal y lingual resulta ser fundament al y la manera más común de hacerlo es mediante la infiltración de soluciones de anestesia local. Entre ellos la lidocaína y articaína son algunos de los más comunes y pueden estar asociado a vasoconstrictores como la epinefrina que puede provocar aumento de la presión arterial y frecuencia cardíaca razón por la cual se hace necesario la monitorización de cambios hemodinámicos durante la cirugía. Describir los cambios hemodinámicos asociados al uso de lidocaína al 2 % y/ o articaína al 4 % en la presión sistólica y diastólica, frecuencia cardiaca y saturación parcial de oxígeno en relación a distintos tiempos operatorios. Se realizó una revisión sistemática en las bases de datos de PubMed, SCOPUS, Web of Science y Sciencedirect. Se analizaron 7 ensayos clínicos controlados en los que utilizaron articaína al 4 % y/o lidocaína al 2 % con epinefrina al 1:100,000 y/o 1:200,000 en volúmenes de 1,8 a 5,4 mL, en los cuales evaluaron la presión sistólica y diastólica, frecuencia cardiaca y saturación parcial de oxígeno en distintos tiempos de la cirugía. Si bien hubo cambios en PAS, PAD, FC y SPO2, todas se mantuvieron dentro de rangos normales bajo el uso de articaína al 4 % y lidocaína al 2 % con epinefrina 1:100,000 y/o 1:200,000 a volúmenes de 1,8 a 5,4mL medidas a distintos tiempos operatorios.


The extraction of lower third molars is one of the most common clinical procedures in which pain control through anesthetic blockade of the lower alveolar, buccal and lingual nerves turns out to be essential and the most common way to do it is through the infiltration of solutions of local anesthesia. Among them, lidocaine and articaine are some of the most common and may be associated with vasoconstrictors such as epinephrine, which can cause an increase in blood pressure and heart rate, which is why it is necessary to monitor hemodynamic changes during surgery. To describe the hemodynamic changes associated with the use of 2 % lidocaine and/or 4 % articaine in systolic and diastolic pressure, heart rate and partial oxygen saturation in relation to different operative times. A systematic review was carried out in the PubMed, SCOPUS, Web of Science and Sciencedirect databases. Seven controlled clinical trials were analyzed in which 4 % articaine and/or 2 % lidocaine were used with epinephrine at 1:100,000 and/or 1:200,000 in volumes of 1,8 to 5,4 mL, in which systolic pressure was evaluated. and diastolic, heart rate and partial oxygen saturation at different times of surgery. Although there were changes in SBP, DBP, HR and SPO2, all remained within normal ranges under the use of 4 % articaine and 2 % lidocaine with epinephrine 1:100,000 and/or 1:200,000 at volumes of 1,8 to 5 .4mL measured at different operative times.


Subject(s)
Humans , Male , Female , Carticaine/therapeutic use , Hemodynamic Monitoring/methods , Anesthetics, Local/therapeutic use , Lidocaine/therapeutic use , Molar, Third/surgery , Surgery, Oral , Hemodynamics/drug effects
6.
Med. U.P.B ; 42(1): 2-9, ene.-jun. 2023. tab
Article in Spanish | LILACS, COLNAL | ID: biblio-1416060

ABSTRACT

Objetivo: determinar el efecto de dos tipos de ayuno sobre parámetros de satisfacción, náuseas, vómito, presión arterial y glucometría en pacientes sometidos a procedimientos de intervencionismo percutáneo bajo anestesia local en un servicio de hemodinámica en Medellín, 2019. Metodología: ensayo clínico aleatorizado abierto de dos brazos en pacientes sometidos a procedimientos de intervencionismo percutáneo bajo anestesia local durante tres meses. Cada brazo con 153 participantes; se asignó un ayuno de seis horas y al grupo de exposición un ayuno de dos horas para alimentos de fácil digestión; no hubo cega­miento, se realizó cálculo de muestra, y se hizo análisis univariado, bivariado y modelo de regresión logística con la variable satisfacción. Resultados: en el grupo de ayuno de seis horas el 2.6% presentó náuseas y en el grupo de exposición el 1.3%; se observó un caso de vómito. La presión arterial y glucometría mostraron diferencias estadísticas sin relevancia clínica. Se encontró significancia esta­dística para mareo, cefalea, hambre, sed y tipo de ayuno respecto con la satisfacción del paciente. Los pacientes con ayuno tuvieron un puntaje de satisfacción entre 60 y 100 y los de dieta ligera entre 82.5 y 100 puntos. Conclusiones: El ayuno de dos horas en dieta ligera mejora la satisfacción de los pa­cientes, disminuye la sensación de hambre, sed, presencia de cefalea y mareo, compa­rado con un ayuno de seis horas. Este estudio no encontró diferencias en las variables hemodinámicas ni en la frecuencia de náuseas y vómito.


Objective: to determine the effect of two types of fasting on parameters of satisfaction, nausea, vomiting, blood pressure and glucose measurement in patients undergoing percutaneous intervention procedures under local anesthesia in a hemodynamic service in Medellín, 2019. Methodology: Two-arm open-label randomized clinical trial in patients undergoing percutaneous interventional procedures under local anesthesia for three months, each arm with 153 participants, who were assigned a six-hour fast and the exposure group a two-hour fast for easily digestible foods. There was no blinding, sample calculation was performed, and univariate and bivariate analysis and logistic regression model were performed with the satisfaction variable. Results: in the six-hour fasting group, 2.6% presented nausea and in the exposure group, 1.3%; one case of vomiting was observed. Blood pressure and blood glucose showed statistical differences without clinical relevance. Statistical significance was found for dizziness, headache, hunger, thirst, and type of fasting with respect to patient satisfaction. Fasting patients had a satisfaction score between 60 and 100 and those on a light diet between 82.5 and 100 points. Conclusions: Fasting for two hours on a light diet improves patient satisfaction, decreases the sensation of hunger, thirst, headache and dizziness, compared to a six-hour fast. This study found no differences in the hemodynamic variables, nor in the frequency of nausea and vomiting.


Objetivo: determinaro efeito de dois tipos de jejum nos parâmetros de satisfação, náuseas, vômitos, pressão arterial e glicemia em pacientes submetidos a procedimentos de intervenção percutânea sob anestesia local em um serviço de hemodinâmica em Medellín, 2019. Metodologia: Ensaio clínico randomizado aberto de dois braços em pacientes submetidos a procedimentos intervencionistas percutâneos sob anestesia local por três meses. Cada braço com 153 participantes; um jejum de seis horas foi designado e o grupo de desafio um jejum de duas horas para alimentos facilmente digeríveis; não houve cegamento, foi realizado cálculo amostral, análise univariada, bivariada e modelo de regressão logística com a variável satisfação. Resultados: no grupo de jejum de seis horas, 2,6% apresentaram náuseas e no grupo de exposição, 1,3%; foi observado um caso de vômito. A pressão arterial e a glicemia apresentaram diferenças estatísticas sem relevância clínica. Foi encontrada significância estatística para tontura, dor de cabeça, fome, sede e tipo de jejum em relação à satisfação do paciente. Os pacientes em jejum tiveram um escore de satisfação entre 60 e 100 e os em dieta light entre 82,5 e 100 pontos. Conclusões: O jejum de duas horas com dieta leve melhora a satisfação do paciente, diminui a sensação de fome, sede, dor de cabeça e tontura, em comparação com o jejum de seis horas. Este estudo não encontrou diferenças nas variáveis hemodinâmicas ou na frequência de náuseas e vômitos.


Subject(s)
Humans , Fasting , Vomiting , Blood Glucose , Patient Satisfaction , Hemodynamics , Anesthesia, Local
7.
REME rev. min. enferm ; 27: 1495, jan.-2023. tab.
Article in English, Portuguese | LILACS, BDENF, CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1518173

ABSTRACT

Objetivo: construir e validar as competências profissionais para enfermeiros atuantes em Unidades de Hemodinâmica. Método: trata-se de uma pesquisa metodológica de construção e validação das competências do enfermeiro de hemodinâmica, aprovada pelo Comitê de Ética em Pesquisa sob protocolo nº 67891517.8.0000.5462 e realizada em instituição pública de cardiologia do estado de São Paulo. Na primeira etapa, foi construído o instrumento para identificar as competências do enfermeiro no setor de hemodinâmica a partir de revisão de literatura e observação local; na segunda, o instrumento foi validade por especialistas. Os dados foram analisados pelo Índice de Validade de Conteúdo (IVC) e média ponderada do IVC. Resultados: a validação das competências ocorreu após duas rodadas de avaliação junto aos especialistas, resultando num total de sete competências relativas ao processo de trabalho da Enfermagem, com média ponderada de IVC entre 88,4 e 99,2 e 74 habilidades, as quais foram classificadas quanto ao tipo de competência; 14 itens foram avaliados como básicos, 10 como intermediários, 34 como avançados e 16 como inconclusivos. Conclusão: as competências profissionais para enfermeiros atuantes em Unidades de Hemodinâmica foram construídas e validadas por especialistas, os quais poderão subsidiar novas diretrizes sobre a formação e a educação permanente dos profissionais nessa área.(AU)


Objective: to build and validate professional skills for nurses working in Hemodynamics Units. Method: this is a methodological study for the construction and validation of hemodynamic nurses' skills, approved by the Research Ethics Committee under protocol number 67891517.8.0000.5462 and carried out in a public institution of cardiology in the state of São Paulo. In the first stage, an instrument was built to identify the skills of nurses in the hemodynamics sector based on a literature review and local observation; in the second, the instrument was validated by specialists. Data were analyzed by Content Validity Index (CVI) and CVI weighted average. Results: competency validation took place after two rounds of evaluation with specialists, resulting in a total of seven competencies related to the Nursing work process, with a weighted average CVI between 88.4 and 99.2 and 74 skills, which were classified according to the type of competence; 14 items were assessed as basic, 10 as intermediate, 34 as advanced and 16 as inconclusive. Conclusion: the professional competences for nurses working in Hemodynamics Units were built and validated by specialists, who can subsidize new guidelines on the formation and permanent education of professionals in this area.(AU)


Objetivo: construir y validar las competencias profesionales para enfermeros que trabajan en Unidades de Hemodinámica. Método: se trata de una investigación metodológica de construcción y validación de las competencias del enfermero de hemodinámica, aprobada por el Comité de Ética en Investigación bajo el protocolo nº 67891517.8.0000.5462 y realizada en la institución pública de cardiología del estado de São Paulo. En la primera etapa, se realizó la construcción de un instrumento para identificar las competencias de los enfermeros en hemodinámica a partir de la revisión bibliográfica y la observación local, y en la segunda etapa, la validación del instrumento por expertos. Los datos se analizaron mediante el Índice de Validez del Contenido (IVC) y la media ponderada del IVC. Resultados: la validación de las competencias se realizó tras dos rondas de evaluación junto a los especialistas, resultando ...(AU)


Subject(s)
Humans , Professional Competence , Education, Nursing/methods , Nurse Practitioners , Practice Guidelines as Topic
8.
Crit. Care Sci ; 35(1): 11-18, Jan. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1448075

ABSTRACT

ABSTRACT Objective: To explain the rationale and protocol of the methods and analyses to be used in the LIVER-PAM randomized clinical trial, which seeks to understand whether a higher mean arterial pressure is capable of reducing the incidence of renal dysfunction postoperatively after liver transplantation. Methods: LIVER-PAM is an open-label, randomized, controlled, singlecenter clinical trial. Patients randomized to the intervention group will have a mean arterial pressure of 85 - 90mmHg in the initial 24 hours of postoperative management, while patients in the control group will have a mean arterial pressure of 65 - 70mmHg in the same period. A sample of 174 patients will be required to demonstrate a 20% reduction in the absolute incidence of renal dysfunction, with a power of 80% and an alpha of 0.05. Conclusion: If a 20% reduction in the absolute incidence of renal dysfunction in the postoperative period of liver transplantation is achieved with higher target mean arterial pressure in the first 24 hours, this would represent an inexpensive and simple therapy for improving current outcomes in the management of liver transplant patients. ClinicalTrials.gov Registry:NCT05068713


RESUMO Objetivo: Explicitar o racional e o protocolo de métodos e análises a serem utilizadas no ensaio clínico randomizado LIVER-PAM, que busca entender se um nível mais alto de pressão arterial média é capaz de reduzir a incidência de disfunção renal no pós-operatório de transplante hepático. Métodos: O LIVER-PAM é um estudo clínico randomizado, controlado, unicêntrico e aberto. Pacientes randomizados para o grupo intervenção terão como alvo de pressão arterial média 85 - 90mmHg nas 24 horas iniciais do manejo pós-operatório, enquanto pacientes do grupo controle terão como alvo de pressão arterial média 65 - 70mmHg no mesmo período. Uma amostra de 174 pacientes será necessária para demonstrar redução de 20% na incidência absoluta de disfunção renal, com poder de 80% e alfa de 0,05. Conclusão: Se a redução de 20% da incidência absoluta de disfunção renal no pós-operatório de transplante hepático for obtida com alvos maiores de pressão arterial média nas primeiras 24 horas, o manejo do paciente nesse cenário encontraria uma terapia barata e simples para a melhoria dos desfechos atuais. Registro Cliniclatrials.gov:NCT05068713

9.
Crit. Care Sci ; 35(1): 107-111, Jan. 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1448077

ABSTRACT

ABSTRACT Cardiac output is an essential determinant of oxygen delivery, although unreliably measured on clinical examination and routine monitoring. Unfortunately, cardiac output monitoring is rarely performed in pediatric critical care medicine, with a limited availability of accurate methods for children. Herein, we report two pediatric cases in which noninvasive pulse-wave transit time-based cardiac output monitoring (esCCO, Nihon Kohden, Tokyo, Japan) was used. The esCCO system calculates cardiac output continuously by using the negative correlation between stroke volume and pulse wave transit time and requires only electrocardiogram monitoring, noninvasive blood pressure, and pulse oximetry signals. Before starting its use, esCCO should be calibrated, which can be done using patient information (gender, age, height, and body weight) or entering cardiac output values obtained by other methods. In both cases, when calibrations were performed using patient information, the agreement between esCCO and echocardiographic measurements was poor. However, after calibration with transthoracic echocardiography, the cardiac output values obtained by both methods remained similar after 2 hours and 18 hours. The results indicate that the esCCO system is suitable for use in children; however, further studies are needed to optimize its algorithm and determine its accuracy, precision, and trend in children.


RESUMO O débito cardíaco é um determinante importante do fornecimento de oxigênio, embora a sua mensuração seja realizada de forma pouco confiável no exame clínico e no monitoramento de rotina. Infelizmente, o monitoramento do débito cardíaco raramente é realizado na medicina intensiva pediátrica, com disponibilidade limitada de métodos precisos para crianças. Relatamos aqui dois casos pediátricos nos quais utilizouse o monitoramento não invasivo do débito cardíaco por meio da análise do tempo de trânsito de ondas de pulso (esCCO, Nihon Kohden, Tóquio, Japão). O sistema esCCO calcula o débito cardíaco continuamente pela correlação negativa entre o volume sistólico e o tempo de trânsito de ondas de pulso e requer apenas o monitoramento por eletrocardiograma, pressão arterial não invasiva e sinais de oximetria de pulso. Antes de iniciar seu uso, o esCCO deve ser calibrado, o que pode ser feito com informações do paciente (sexo, idade, altura e peso corporal) ou informando os valores do débito cardíaco obtidos mediante outros métodos. Em ambos os casos, quando as calibragens foram realizadas com informações do paciente, a concordância entre o débito cardíaco contínuo estimado e as medidas ecocardiográficas foi insatisfatória. Entretanto, após a calibragem com ecocardiografia transtorácica, os valores do débito cardíaco obtidos pelos dois métodos permaneceram semelhantes após 2 horas e 18 horas. Os resultados indicam que o sistema esCCO pode ser útil em crianças; entretanto, são necessários mais estudos para otimizar seu algoritmo e determinar sua exatidão, precisão e tendência em crianças.

10.
Rev. urug. cardiol ; 38(1): e403, 2023. ilus, tab
Article in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1450410

ABSTRACT

Introducción: la monitorización hemodinámica constituye un conjunto de técnicas y parámetros que permiten valo rar si la función cardiovascular es la adecuada para mantener la perfusión y la oxigenación tisular que permita sa tisfacer las demandas metabólicas del organismo, valorar el estado y el comportamiento del sistema cardiovascular, orientando sobre la mejor estrategia terapéutica. La presente revisión busca proporcionar una descripción general e integrada de las diferentes técnicas de monitorización, así como aspectos fisiológicos relevantes para su entendi miento y empleo terapéutico. La monitorización hemodinámica acompañada de un adecuado conocimiento de la fisiología cardiovascular permite determinar el estado del sistema cardiovascular, la condición hemodinámica del paciente y la estrategia terapéutica requerida. Su interpretación debe partir de la integración y la correlación de diversos parámetros hemodinámicos.


Introduction: hemodynamic monitoring is a set of techniques and parameters that allow evaluating whether cardio vascular function is adequate to maintain tissue perfusion and oxygenation to satisfy metabolic demands of the or ganism, assess the condition and behavior of the cardiovascular system, providing guidance on the best therapeutic strategy. This review seeks to provide a general and integrated description of the different monitoring techniques, as well as physiological aspects relevant to their understanding and therapeutic use. Hemodynamic monitoring accompanied by an adequate knowledge of cardiovascular physiology allows to determine the state of the cardiovascular system, hemodynamic condition of the patient and therapeutic strategy required, its interpretation must start from the integration and correlation of different hemodynamic parameters.


Introdução: a monitorização hemodinâmica constitui um conjunto de técnicas e parâmetros que permitem avaliar se a função cardiovascular é adequada para manter a perfusão e oxigenação tecidual que permite satisfazer as exi gências metabólicas do organismo, avaliar o estado e comportamento do sistema cardiovascular, orientando sobre a melhor estratégia terapêutica. Esta revisão procura fornecer uma descrição geral e integrada das diferentes técnicas de monitorização, bem como aspectos fisiológicos relevantes para a sua compreensão e utilização terapêutica. A monitorização hemodinâmica acompanhada de um conhecimento adequado da fisiologia cardiovascular permite determinar o estado do sistema cardiovascular, a condição hemodinâmica do doente e a estratégia terapêutica neces sária, a sua interpretação deve partir da integração e correlação de vários parâmetros hemodinâmicos.


Subject(s)
Humans , Cardiovascular Physiological Phenomena , Critical Illness/therapy , Hemodynamic Monitoring/methods , Blood Gas Analysis/methods , Echocardiography/methods , Critical Care/methods
11.
Arq. bras. oftalmol ; 86(5): e20230065, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527804

ABSTRACT

ABSTRACT Purpose: The study aimed to investigate the correlation between arterial hemodynamics measured by color Doppler ultrasonography and retinal microarchitecture parameters determined by spectral-domain optical coherence tomography (SD-OCT) in pseudoexfoliation glaucoma. Methods: This prospective study included 82 participants. Peripapillary retinal nerve fiber layer, ganglion cell inner plexiform layer, and ganglion cell complex values were measured. Ophthalmic artery and central retinal artery flows were evaluated with color Doppler ultrasonography, and resistivity index values were calculated. Results: The study included 47 controls and 35 pseudoexfoliation glaucoma cases. In pseudoexfoliation glaucoma group, mean peripapillary retinal nerve fiber layer and ganglion cell complex thickness were statistically significantly lower in all quadrants compared to controls (p<0.001). Resistivity index values of the ophthalmic and central retinal arteries were significantly higher in pseudoexfoliation glaucoma group than in the controls (p<0.001 and r=0.684). Resistivity index values of the ophthalmic and central retinal arteries with ganglion cell complex thickness correlated significantly. On the other hand, no significant relationship for retinal nerve fiber layer thickness was identified. Conclusions: Structural changes (ganglion cell complex and ganglion cell inner plexiform layer) in patients with pseudoexfoliation glaucoma and early glaucomatous loss showed a significant correlation with changes in ocular vascular hemodynamics. In cases where systemic vascular resistance is increased, ganglion cell complex and ganglion cell inner plexiform layer may not exactly reflect glaucoma state. In such cases, thickness changes in the retinal nerve fiber layer may give more realistic results regarding glaucoma. We have seen that pseudoexfoliation glaucoma-induced structural deterioration and increased resistance in ocular hemodynamics correlated with ganglion cell complex, but not retinal nerve fiber layer.


RESUMO Objetivo: Investigar a correlação entre a hemodi­nâmica arterial, medida pela ultrassonografia com Doppler colorido, e os parâmetros de microarquitetura da retina, determinados pela tomografia de coerência óptica de domínio espectral (SD-OCT) no glaucoma pseudoexfoliativo. Métodos: Foram incluídos 82 participantes neste estudo prospectivo. Foram medidos os valores da camada de fibras nervosas da retina peripapilar, da camada plexiforme interna de células ganglionares e do complexo de células ganglionares. Os fluxos da artéria oftálmica e da artéria central da retina foram avaliados com ultrassonografia por Doppler colorida e foram calculados os valores do índice de resistividade. Resultados: Foram incluídos no estudo 47 casos de controle e 35 casos de glaucoma pseudoexfoliativo. No grupo com glaucoma pseudoexfoliativo, a média da camada de fibras nervosas da retina peripapilar e a espessura do complexo de células ganglionares foram menores em todos os quadrantes em comparação com os controles, com significância estatística (p<0,001). Os valores do índice de resistividade das artérias oftálmica e central da retina foram significativamente maiores no grupo com glaucoma pseudoexfoliativo que nos controles (p<0,001 e r=0,684). Ao se compararem os valores do índice de resistividade das artérias oftálmica e central da retina com a espessura do complexo de células ganglionares, foi encontrada uma correlação significativa entre elas. Por outro lado, não detectamos uma relação significativa para a espessura da camada de fibras nervosas da retina. Conclusões: Alterações estruturais (complexo de células ganglionares, camada plexiforme interna de células ganglionares) em pacientes com glaucoma pseudoexfoliativo com perda glaucomatosa precoce mostraram uma correlação significativa com alterações na hemodinâmica vascular ocular. Nos casos em que a resistência vascular sistêmica é aumentada, o complexo de células ganglionares e a camada plexiforme interna de células ganglionares podem não refletir exatamente o estado do glaucoma. Nesses casos, alterações na espessura da camada de fibras nervosas da retina podem dar resultados mais realistas em relação ao glaucoma. Observou-se uma correlação da deterioração estrutural induzida pelo glaucoma pseudoexfoliativo e do aumento da resistência na hemodinâmica ocular com o complexo de células ganglionares, mas não com a camada de fibras nervosas da retina.

12.
Fisioter. Pesqui. (Online) ; 30: e23020323en, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1528629

ABSTRACT

ABSTRACT The literature on hemodynamic responses during inspiratory muscle exercise (IME) lacks a consensus. To evaluate and compare hemodynamic responses during an IME session with and without resistive load, 15 sedentary men were subjected to two randomized IME sessions: one with 40% of maximal inspiratory pressure (IME 40%) and another without a resistive load (Sham), both of which were performed for two minutes over eight sessions with one-minute intervals. Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP), total peripheral resistance (TPR), stroke volume (SV), cardiac output (CO), and heart rate (HR) were measured by infrared digital photoplethysmography during five basal minutes and during the IME sessions. One-way analysis of variance and the Student's t test for paired data were used to analyze hemodynamic response and delta values between sessions. Effect size was evaluated by Cohen's D. A 5% significance level was adopted. SBP responses (sham: ∆−1±2 vs. 40%: ∆−4±2mmHg, p=0.27), DBP (sham: ∆2±1 vs. 40%: ∆1±2mmHg, p=0.60) and MBP (sham: ∆2±1 vs. 40%: ∆0±2mmHg, p=0.28) were similar between sessions. HR increases were higher in the 40% IME session than in the sham session (sham: ∆9±2 vs. 40%: ∆3±2bpm, p=0.001). SV only decreased during the sham session but responses were similar between sessions (sham: ∆−2±2 vs. IME 40%: ∆−6±2ml, p=0.13). Both sessions did not change SBP, DBP, MBP, CO, and TPR, but we observed a greater increase in HR in the IME 40% session. Only the Sham session decreased SV.


RESUMEN No hay consenso en la literatura sobre las respuestas hemodinámicas durante el ejercicio muscular inspiratorio (EMI). El objetivo de este estudio fue evaluar y comparar las respuestas hemodinámicas durante una sesión de EMI con y sin carga resistiva. Para ello, quince hombres sedentarios recibieron dos sesiones aleatorias de EMI: el 40% de la presión inspiratoria máxima (EMI 40%) y sin carga resistiva (sham), realizadas durante dos minutos, ocho sesiones y a intervalos de un minuto. La presión arterial sistólica (PAS), la presión arterial diastólica (PAD), la presión arterial media (PAM), la resistencia periférica total (RPT), el volumen sistólico (VS), el gasto cardíaco (GC) y la frecuencia cardíaca (FC) se midieron mediante fotopletismografía infrarroja digital durante cinco minutos al inicio y durante las sesiones de EMI. Se utilizaron ANOVA unidireccional y la prueba t de Student a datos emparejados para analizar la respuesta hemodinámica y los valores delta entre las sesiones. El tamaño del efecto se evaluó por el d de Cohen. El nivel de significancia adoptado fue de 5%. Las respuestas de PAS (sham: Δ−1±2 vs. 40%: ∆−4±2mmHg, p=0,27), PAD (sham: ∆2±1 vs. 40%: ∆1±2mmHg, p=0,60) y PAM (sham: ∆2±1 vs. 40%: ∆0±2mmHg, p=0,28) fueron similares entre las sesiones. El incremento de la FC fue mayor en la sesión de EMI 40% comparada con la sesión sham (sham: Δ9±2 vs. 40%: ∆3±2bpm, p=0,001). El VS tuvo una disminución exclusiva durante la sesión sham, pero la respuesta fue similar entre las sesiones (sham: Δ−2±2 vs. EMI 40%: ∆−6±2ml, p=0,13). Ambas sesiones no tuvieron cambios en las variables PAS, PAD, PAM, DC y RPT, pero se observó un mayor incremento de la FC en la sesión EMI 40%. Solamente en la sesión sham hubo una reducción del VS.


RESUMO A literatura carece de um consenso sobre respostas hemodinâmicas durante o exercício muscular inspiratório (EMI). Este estudo buscou avaliar e comparar as respostas hemodinâmicas durante uma sessão de EMI com e sem carga resistiva. Para tanto, 15 homens sedentários foram submetidos a duas sessões randomizadas de EMI: 40% da pressão inspiratória máxima (EMI 40%) e sem carga resistiva (sham), realizadas por dois minutos em oito sessões e com intervalos de um minuto. A pressão arterial sistólica (PAS), pressão arterial diastólica (PAD), pressão arterial média (PAM), resistência periférica total (RPT), volume sistólico (VS), débito cardíaco (DC) e frequência cardíaca (FC) foram medidos por fotopletismografia infravermelha digital por cinco minutos basais e durante as sessões de EMI. Anova de uma via e o teste t de Student para dados pareados foram usados para analisar a resposta hemodinâmica e os valores delta entre as sessões. O tamanho do efeito foi avaliado pelo d de Cohen. Adotou-se nível de significância de 5%. As respostas de PAS (sham: ∆−1±2 vs. 40%: ∆−4±2mmHg, p=0,27), PAD (sham: ∆2±1 vs. 40%: ∆1±2mmHg, p=0,60) e PAM (sham: ∆2±1 vs. 40%: ∆0±2mmHg, p=0,28) foram semelhantes entre as sessões. Os aumentos da FC foram maiores na sessão de EMI 40% do que nas sessões sham (sham: ∆9±2 vs. 40%: ∆3±2bpm, p=0,001). O VS diminuiu exclusivamente durante a sessão sham mas a resposta foi semelhante entre as sessões (sham: ∆−2±2 vs. EMI 40%: ∆−6±2ml, p=0,13). Ambas as sessões não causaram alteração nas variáveis PAS, PAD, PAM, DC e RPT, mas notamos um aumento maior da FC na sessão EMI 40%. Apenas a sessão sham reduziu o VS.

13.
Montevideo; s.n; 2023. 63 p. tab, graf.
Thesis in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1518916

ABSTRACT

Introducción. La variación de la velocidad máxima aórtica con la ventilación mecánica (ΔVpeakAo) ha demostrado ser el mejor predictor de respuesta a volumen en pediatría. Existe evidencia en adultos de que la variación de velocidad máxima de flujo carotídeo (ΔVpeakCar) es predictor de respuesta a fluidos. Al momento es escasa la información sobre este índice en pediatría. Su beneficio se basa en la no-invasividad, y que para su medición no es necesaria la ecocardiografía ni el acceso al tórax del paciente. Objetivo. El objetivo general de este trabajo fue estudiar la correlación y la concordancia de ΔVpeakCar con ΔVpeakAo en una población pediátrica bajo ventilación mecánica. Metodología. Se incluyeron pacientes de 0 a 12 años. Se registraron flujos aórtico y carotídeos máximos y mínimos y se calculó ΔVpeakCar y ΔVpeakAo. Para analizar correlación y concordancia entre las variables se utilizó el test de Pearson, análisis de Bland-Altman y análisis de los 4-cuadrantes. Resultados. Se estudiaron 58 pacientes, 13 lactantes (menores 12 meses), 21 preescolares (12-60 meses) y 24 escolares (mayores a 60 meses). Se observó una correlación significativa entre ΔVpeakAo y ΔVpeakCar (r=0,85; p<0,05) con un coeficiente de determinación de r2=0,72. El análisis de Bland-Altman mostró un sesgo del 0,15% (IC95%, -0.7-1.0) con un límite de concordancia del -6,1 a 6,2%. La concordancia fue 85%, con un sesgo angular de 4,5°±31°. El análisis por subgrupos mostró un r2 de 0.89 en escolares, 0.56 en preescolares y 0.45 en lactantes. La concordancia fue de 100% en escolares, 95% en prescolares y 93% en lactantes. Discusión y conclusiones. El registro de ΔVpeakCar fue viable. Al analizar la capacidad de ΔVpeakCar de sustituir a ΔVpeakAo en el total de la muestra, no es buena La correlación y concordancia son mejores en escolares. Es necesario continuar estudiando este nuevo índice.


Introduction. The variation in maximum aortic velocity with mechanical ventilation (ΔVpeakAo) has proven to be the most effective predictor of fluid response in pediatrics. While there is evidence in adults that the variation in maximum carotid flow velocity (ΔVpeakCar) predicts fluid response, information on this index in pediatrics remains limited. Its advantage lies in its non-invasive nature, eliminating the need for echocardiography or thoracic access for recording. Objective. This study aims to examine the correlation and concordance between ΔVpeakCar and ΔVpeakAo in a pediatric population. Methodology. The study included patients aged 0 to 12 years. Maximum and minimum aortic and carotid flows were recorded, and ΔVpeakCar and ΔVpeakAo were calculated. Correlation and agreement between variables were analyzed using the Pearson test, Bland Altman analysis, and 4-quadrant analysis. Results. A total of 58 patients were studied, comprising 13 infants (under 12 months), 21 preschoolers (12-60 months), and 24 school-aged children (over 60 months). A significant correlation was observed between ΔVpeakAo and ΔVpeakCar (r=0.85; p<0.05) with a coefficient of determination, r²=0.72. The Bland-Altman analysis revealed a bias of 0.15% (95% CI, -0.7-1.0) with an agreement limit of -6.1% to 6.2%. The concordance rate was 85%, with an angular bias of 4.5°±31°. Subgroup analysis showed r² values of 0.89 in school-aged children, 0.56 in preschoolers, and 0.45 in infants. Concordance rates were 100% in school-aged children, 95% in preschoolers, and 93% in infants. Discussion and Conclusions. The measurement of ΔVpeakCar proved feasible. However, when considering its ability to replace ΔVpeakAo, the results are suboptimal. Correlation and concordance are stronger in school-aged children. Further investigation into this new index is warranted.


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Respiration, Artificial , Elective Surgical Procedures , Hemodynamic Monitoring , Anesthesia, General
14.
J. Transcatheter Interv ; 312023. tab; ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1435514

ABSTRACT

Introdução: Face à melhor compreensão da fisiopatologia da estenose valvar aórtica, cresceu paralelamente a complexidade da avaliação de sua gravidade, persistindo relevante incerteza quanto à aplicabilidade dos métodos invasivos pelo cateterismo cardíaco e os não invasivos, com base em ecocardiografia. O objetivo deste estudo foi analisar os padrões hemodinâmicos da avaliação com ecocardiografia comparativamente à estimativa da gravidade da estenose aórtica com o cateterismo em pacientes consecutivos referidos para avaliação diagnóstica por laboratório de hospital acadêmico terciário no triênio 2016-2018. Métodos: Estudo observacional, descritivo e retrospectivo das características clínicas e dos resultados das avaliações da gravidade da estenose valvar aórtica obtidas em 96 pacientes consecutivos, por meio de cateterismo e ecocardiografia. Resultados: Amostra populacional de 49 homens e 47 mulheres, com mediana de idade de 66,5 (56,5 a 72,8) anos, estenose valvar aórtica degenerativa em 49% e reumática em 40%, além de diversas comorbidades, inclusive doença coronária (37%). Pelo cateterismo, com base no gradiente pico de 48 (20 a 68), a estenose valvar aórtica foi avaliada como grave em 56%, sendo a pressão telediastólica ventricular de 20mmHg (16 a 30mmHg). Pela ecocardiografia, a área valvar foi 0,9cm2 (0,7 a 1,2cm2), sendo indexado 0,5cm2/m2 (0,43 a 0,5cm2/m2), com gradiente pico de 62±26 mmHg. A estenose valvar aórtica foi considerada severa em 69,2%. Houve discordância entre os métodos sobre a severidade da estenose valvar aórtica em 30% dos exames, com coeficiente de Spearman entre área valvar pelo ecocardiograma e gradiente pico pelo cateterismo de -0,7 (p<0,001). Conclusão: Em amostra representativa dos vários padrões hemodinâmicos, a avaliação da gravidade da estenose valvar aórtica, como praticada rotineiramente em laboratório acadêmico, limitou-se à medida de pico de gradiente transvalvar. A estimativa da área valvar pelo método ecocardiográfico, sendo indireta e também passível de crítica, contribui para as discrepâncias encontradas, tornando-se justificável buscar o aperfeiçoamento de ambos os métodos, em vista da complexidade clínica e hemodinâmica detectada.


Background: In view of the better understanding of the pathophysiology of aortic valve stenosis, the complexity of assessing its severity has simultaneously grown, with relevant uncertainty persisting as to the applicability of invasive methods by cardiac catheterization and non-invasive methods based on echocardiography. The objective of this study was to analyze the hemodynamic patterns of evaluation with echocardiography compared to the estimation of severity of aortic stenosis with catheterization in consecutive patients referred for diagnostic evaluation by the laboratory of a tertiary academic hospital in the 2016 to 2018 triennium. Methods: An observational, descriptive and retrospective study of clinical characteristics and results of assessments of severity of aortic valve stenosis obtained in 96 consecutive patients, through catheterization and echocardiography. Results: A population sample of 49 men and 47 women, with a median age of 66.5 (56.5 to 72.8) years, degenerative aortic valve stenosis in 49%, and rheumatic aortic stenosis in 40%, in addition to several comorbidities, including coronary disease (37%). Using catheterization, based on the peak gradient of 48 (20 to 68), aortic valve stenosis was assessed as severe in 56%, with ventricular end-diastolic pressure of 20mmHg (16 to 30mmHg). Using echocardiography, the valve area was 0.9cm2 (0.7 to 1.2cm2), indexed valve area was 0.5cm2/m2 (0.43 to 0.5cm2/m2), with peak gradient of 62±26mmHg. Aortic valve stenosis was considered severe in 69.2%. There was disagreement between the methods regarding severity of aortic valve stenosis in 30% of exams, with a Spearman coefficient between the valve area on the echocardiogram and the peak gradient on catheterization of -0.7 (p<0.001). Conclusion: In a representative sample of various hemodynamic patterns, the assessment of severity of aortic valve stenosis, as routinely practiced in an academic laboratory, was limited to measuring the peak transvalvular gradient. The estimation of the valve area using the echocardiographic method was indirect and also subject to criticism, and contributed to the discrepancies found, rendering it justifiable to seek the improvement of both methods, in view of the clinical and hemodynamic complexity detected.

15.
J. Transcatheter Interv ; 31: eA20230003, 2023.
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1428063

ABSTRACT

Anomalias coronarianas são menos frequentes em relação às doenças coronarianas adquiridas, como a aterosclerose, e têm sido implicadas como causa de eventos cardiovasculares. Este relato de caso descreve um achado incidental por angiografia de coronária direita anômala com origem no seio coronariano esquerdo e trajeto intra-arterial, após episódio de morte súbita abortada. A análise do Heart Team indicou como melhor tratamento a abordagem percutânea com implante de stent farmacológico em origem de coronária direita, procedimento este que foi realizado com sucesso. Este relato de caso e estudos recentes têm demonstrado que o tratamento percutâneo de anomalias coronarianas é uma opção segura para pacientes selecionados, levando em consideração quadro clínico, estudo anatômico e capacitação da equipe de hemodinâmica


Coronary anomalies are less frequent than acquired coronary diseases, such as atherosclerosis, and have been implicated as a cause of cardiovascular events. This case report describes an incidental finding on angiography of an anomalous right coronary artery with origin in the left coronary sinus and an intra-arterial course, after an episode of aborted sudden death. The Heart Team analysis indicated a percutaneous approach with drug-eluting stent implantation at the origin of the right coronary artery as the best treatment, and the procedure was successfully performed. This case report and recent studies have demonstrated percutaneous treatment of coronary anomalies is a safe option for selected patients, considering clinical presentation, anatomy study, and training of the cath lab team

16.
Arq. bras. cardiol ; 120(4): e20220398, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1429806

ABSTRACT

Resumo A pressão arterial central (PAc) é considerada um preditor independente de lesão de órgão, eventos cardiovasculares e mortalidade por todas as causas. Evidências mostram que o treino intervalado de alta intensidade (HIIT) é superior ao treino contínuo de intensidade moderada (MICT) na melhoria da aptidão cardiorrespiratória e da função vascular. No entanto, os efeitos dessas modalidades de treino aeróbico sobre a PAc não foram propriamente revisados. Esta metanálise tem como objetivo investigar os efeitos do HIIT versus MICT sobre a PAc.Conduzimos uma metanálise de ensaios controlados randomizados que compararam HIIT versus MICT sobre a PAc. Os desfechos primários foram Pressão Arterial Sistólica (PAS) central (PASc) e Pressão Arterial Diastólica central (PADc). A PAS periférica (PASp), a PAD periférica (PADp), a Velocidade de Onda de Pulso (VOP) e a captação máxima de oxigênio (VO2max) foram analisadas como desfechos secundários. A metanálise das diferenças médias (DM) foi conduzida usando modelos de efeitos aleatórios.Nosso estudo incluiu 163 pacientes recrutados em seis ensaios. Encontramos que HIIT foi superior ao MICT em reduzir PASc (DM = -3,12 mmHg, IC95% -4,75 - 1,50, p = 0,0002) e PAS (DM = -2,67 mmHg, IC95% -5,18 - -0,16, p = 0,04) e aumentar VO2max (DM = 2,49 mL/Kg/min, IC95% 1,25 - 3,73, p = 0,001). No entanto, não foram relatadas diferenças quanto à PADc, PAD ou VOP. O HIIT foi superior ao MICT em reduzir PASc, sugerindo seu potencial papel como uma terapia não farmacológica para a pressão arterial elevada.


Abstract Central blood pressure (cBP) is considered an independent predictor of organ damage, cardiovascular events and all-cause mortality. Evidence has shown that high intensity interval training (HIIT) is superior to moderate-intensity continuous training (MICT) for improving cardiorespiratory fitness and vascular function. However, the effects of these aerobic training modalities on cBP have not yet been properly reviewed.This meta-analysis aims to investigate to effects of HIIT versus MICT on cBP.We conducted a meta-analysis of randomized controlled trials that compared HIIT versus MICT on cBP. Primary outcomes were measures of central systolic blood pressure (cSBP) and central diastolic blood pressure (cDBP). Peripheral systolic blood pressure (pSBP) and diastolic blood pressure (pDBP), pulse wave velocity (PWV) and maximal oxygen uptake (VO2max) were analyzed as second outcomes. Meta-analysis of mean differences (MD) was conducted using the random effects model.Our study included 163 patients enrolled in six trials. We found that HIIT was superior to MICT in reducing the cSBP (MD = -3.12 mmHg, 95% CI: -4.75 to -1.50, p = 0.0002) and SBP (MD = -2.67 mmHg, 95% CI: -5.18 to -0.16, p = 0.04), and increasing VO2max(MD = 2.49 mL/kg/min, 95% CI: 1.25 to 3.73, p = 0.001). However, no significant differences were reported for cDBP, DBP and PWV.HIIT was superior to MICT in reducing the cSBP, which suggests its potential role as a non-pharmacological therapy for high blood pressure.

17.
Crit. Care Sci ; 35(2): 117-146, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1448100

ABSTRACT

ABSTRACT Echocardiography in critically ill patients has become essential in the evaluation of patients in different settings, such as the hospital. However, unlike for other matters related to the care of these patients, there are still no recommendations from national medical societies on the subject. The objective of this document was to organize and make available expert consensus opinions that may help to better incorporate echocardiography in the evaluation of critically ill patients. Thus, the Associação de Medicina Intensiva Brasileira, the Associação Brasileira de Medicina de Emergência, and the Sociedade Brasileira de Medicina Hospitalar formed a group of 17 physicians to formulate questions relevant to the topic and discuss the possibility of consensus for each of them. All questions were prepared using a five-point Likert scale. Consensus was defined a priori as at least 80% of the responses between one and two or between four and five. The consideration of the issues involved two rounds of voting and debate among all participants. The 27 questions prepared make up the present document and are divided into 4 major assessment areas: left ventricular function, right ventricular function, diagnosis of shock, and hemodynamics. At the end of the process, there were 17 positive (agreement) and 3 negative (disagreement) consensuses; another 7 questions remained without consensus. Although areas of uncertainty persist, this document brings together consensus opinions on several issues related to echocardiography in critically ill patients and may enhance its development in the national scenario.


RESUMO A ecocardiografia do paciente grave tem se tornado fundamental na avaliação de pacientes em diferentes cenários e ambientes hospitalares. Entretanto, ao contrário de outras áreas relativas ao cuidado com esses pacientes, ainda não existem recomendações de sociedades médicas nacionais acerca do assunto. O objetivo deste documento foi organizar e disponibilizar opiniões de consenso de especialistas que possam auxiliar a melhor incorporação dessa técnica na avaliação de pacientes graves. Dessa forma, a Associação de Medicina Intensiva Brasileira, a Associação Brasileira de Medicina de Emergência e a Sociedade Brasileira de Medicina Hospitalar compuseram um grupo de 17 médicos para formular questões pertinentes ao tópico e debater a possibilidade de consenso de especialistas para cada uma delas. Todas as questões foram elaboradas no formato de escala Likert de cinco pontos. Consenso foi definido, a priori, como um somatório de, ao menos, 80% das respostas entre um e dois ou entre quatro e cinco. A apreciação das questões envolveu dois ciclos de votação e debate entre todos os participantes. As 27 questões elaboradas compõem o presente documento e estão divididas em 4 grandes áreas de avaliação: da função ventricular esquerda; da função ventricular direita; diagnóstica dos choques e hemodinâmica. Ao fim do processo, houve 17 consensos positivos (concordância) e 3 negativos (discordância); outras 7 questões persistiram sem consenso. Embora persistam áreas de incerteza, este documento reúne opiniões de consenso para diversas questões relativas à ecocardiografia do paciente grave e pode potencializar seu desenvolvimento no cenário nacional.

19.
Rev. colomb. anestesiol ; 50(3): e501, July-Sept. 2022. graf
Article in English | LILACS | ID: biblio-1388937

ABSTRACT

Abstract Pheochromocytomas are neuroendocrine tumors capable of synthetizing, storing and releasing catecholaminergic hormones that may lead to lifethreatening hemodynamic instability. The COVID-19 pandemic has increased the risks and perioperative complexity of the patients undergoing pheochromocytoma-associated adrenalectomy. This article discusses the use of adenosine for the management of hypertensive crisis during this intervention, as well as the need to individualize the suitable timing for surgery after recent COVID-19 infection. This article discusses the case of a patient with a finding of right adrenal incidentaloma; further studies determined a metanephrines secreting pheochromocytoma. Following hospital admission for preoperative optimization, the eve of the procedure the patient developed an acute myocardial infarction and subsequently SARS-CoV-2 symptomatic infection. Intraoperatively, hypertensive peaks were managed with continuous adenosine perfusion. The patient was discharged after 48 hours. Preoperative optimization positively influences the intraoperative management of patients with pheochromocytoma. The intraoperative use of adenosine allows for adequate and safe control of hypertensive crises. Each situation must be individualized in patients pending surgery, with a recent COVID-19 infection.


Resumen Los feocromocitomas son tumores neuroendocrinos capaces de sintetizar, almacenar y liberar hormonas catecolaminérgicas que pueden provocar inestabilidad hemodinámica con compromiso vital. La pandemia por COVID-19 ha aumentado los riesgos y la complejidad perioperatoria de los pacientes sometidos a adrenalectomía por feocromocitoma. Describimos el uso de adenosina para manejar las crisis hipertensivas durante esta intervención, así como establecer la necesidad de individualizar el momento quirúrgico idóneo tras infección reciente por COVID-19. Presentamos el caso de un paciente con hallazgo de incidentaloma suprarrenal derecho cuya ampliación de estudio se orientó como feocromocitoma secretor de metanefrinas. Tras ingreso hospitalario para optimización preoperatoria, el día previo al procedimiento presentó un infarto agudo de miocardio y posteriormente una infección sintomática por SARS-CoV-2. Intraoperatoriamente se manejaron los picos hipertensivos con perfusión continua de adenosina. Tras 48 horas recibió el alta hospitalaria. La optimización preoperatoria influye positivamente en el manejo intraoperatorio de los pacientes con feocromocitoma. El uso intraoperatorio de adenosina permite un adecuado y seguro control de las crisis hipertensivas. En pacientes pendientes de cirugía con infección reciente por COVID-19 se requiere individualizar cada situación.


Subject(s)
Pancreas Divisum
20.
Cambios rev. méd ; 21(1): 719, 30 Junio 2022. ilus, grafs.
Article in Spanish | LILACS | ID: biblio-1402501

ABSTRACT

INTRODUCCIÓN. La estimulación cardíaca temporal de larga duración con cable activo y marcapaso permanente externo es una técnica recientemente incluida en las guías de manejo de bradicardias sintomáticas. CASOS CLÍNICOS. Se describen 4 casos de pacientes sometidos a estimulación cardíaca temporal de larga duración con cable activo y marcapaso permanente externo de la unidad de Hemodinámica del Hospital de Especialidades Carlos Andrade Marín, con indicaciones diversas. DISCUSIÓN. El tiempo medio de permanencia con el cable activo y el marcapaso externalizado fue 23 días. No hubo complicaciones del procedimiento. Un paciente falleció por causas no relacionadas con la estimulación y 2 se recuperaron en sus domicilios. CONCLUSIÓN. La técnica de estimulación temporal utilizando marcapasos permanentes recuperados se muestra extremadamente útil para mantener un marcapaso cardíaco seguro, incluso ambulatorio y por largo tiempo, hasta el implante de dispositivos definitivos. Su limitación es la factibilidad de hacerlo solo en centros de tercer nivel.


INTRODUCTION. Long-duration temporary cardiac pacing with active lead and permanent external pacemaker is a technique recently included in the guidelines for the management of symptomatic bradycardias. CLINICAL CASES. We describe 4 cases of patients who underwent long-duration temporary cardiac pacing with active lead and external permanent pacemaker at the Hemodynamics Unit of the Hospital de Especialidades Carlos Andrade Marín, with different indications. DISCUSSION. The mean length of stay with the active lead and externalized pacemaker was 23 days. There were no procedural complications. One patient died of causes unrelated to pacing and 2 recovered at home. CONCLUSIONS. The technique of temporary pacing using retrieved permanent pacemakers is extremely useful for maintaining safe cardiac pacing, even on an outpatient basis and for a long period of time, until implantation of definitive devices. Its limitation is the feasibility of doing it only in third level centers.


Subject(s)
Humans , Male , Female , Adult , Aged , Aged, 80 and over , Pacemaker, Artificial , Bradycardia , Cardiology , Heart , Heart Rate , Hemodynamics , Prostheses and Implants , Tertiary Healthcare , Cardiac Pacing, Artificial , Advanced Cardiac Life Support , Ecuador , Endocarditis , Hospital Care , Heart Arrest , Heart Ventricles , Anti-Bacterial Agents
SELECTION OF CITATIONS
SEARCH DETAIL